Get a Quote

Recommended Products

Our products have occupied many markets all over the world.

If you want to know more, please contact us.

We not only provide a good product, but also provide high quality service. If you are interested in our products,you can contact us in the following ways.

Request a personalized quote
Chiller Sizing Form North Slope Chillers

Chiller Sizing Form North Slope Chillers

Aug 19, 2020 Use the North Slope Chillers Selection Not sure which North Slope Chiller is best for your application? Our Chiller Search Tool can help you narrow down your choices to make sure you get exactly what you require. Simply fill in the cooling requirements, and we will identify the right chiller for you in the results.

Get Details
SIZING THE CHILLED WATER BUFFER TANKS - Amtrol

SIZING THE CHILLED WATER BUFFER TANKS - Amtrol

Check with Chiller Manufacturer for specific requirements. Typical HVAC chiller systems are between 3 to 6 gallons per ton. While 6 to 10 gallons are used for applications in which temperature accuracy is critical. Volume of Total Buffer Tank = (C x V R) - V A ( TON X GAL TON) - GAL = Required Information for Properly Sized Chilled Water Buffer ...

Get Details
How To Size A Chiller - Petra UK

How To Size A Chiller - Petra UK

Chillers are used to reject heat from e.g. buildings or industrial processes by means of cooling water. Proper sizing of a chiller is crucial to ensuring that the correct chiller is selected. The …

Get Details
Details Home - Parker Hannifin

Details Home - Parker Hannifin

Dec 11, 2019 Configuration of generously sized water tank coupled with oversized condenser/evaporator allows the chiller to maintain cooling capacity even during rapid load and water temperature changes. High reliability, with energy management, to reduce total cost of ownership. Low water temperature options (down to -10C) available for enhanced cooling.

Get Details
Thermex Industrial Chillers

Thermex Industrial Chillers

Industrial Chillers. We draw on over 50 years experience to design, build and produce industry leading Industrial Chiller solutions for your business. We understand the Australian commercial HVAC industry inside our and have unrivalled knowledge across designing and building water chillers, critical cooling solutions and drinking water products.

Get Details
3HP Small size industrial water cooled chiller

3HP Small size industrial water cooled chiller

Industrial water cooled chiller Quick Details. :water cooled chiller Cooling capacity range: 2Ton to 50Ton. :Temperature control 5℃ to 35℃. :Water cooled condenser type: shell and tube. :Build in stainless steel water tank and water pump. :Scroll or piston compressor available. :Schneider electrical components. :Mic-computer ...

Get Details
Industrial Process Water Chillers - T. J. Snow Co.

Industrial Process Water Chillers - T. J. Snow Co.

Koolant Koolers. Koolant Koolers is a manufacturer of industrial-grade water chillers from standard small 1/8 ton units to over 500 tons. The Koolant Koolers chiller is best known for its trusted standard and custom cooling solutions for the machine tool, food processing and packaging, and medical diagnostic imaging markets.

Get Details
Chiller - Factors That Influence the Size of the Chiller

Chiller - Factors That Influence the Size of the Chiller

Mar 12, 2021 Calculations of Chiller’s Cooling Efficiency. To properly scale chillers, you must first calculate the cooling load. The formula below will assist you in determining the appropriate cooling capability. kW = 4.186 x m 3/h x Temperature Difference (delta T) / 3.6 BTU/ hour = 500 x GPM x Temperature Difference (delta T).

Get Details
Chiller Sizing Guidelines Made Easy Conair

Chiller Sizing Guidelines Made Easy Conair

Mar 25, 2019 To size a chiller to meet your requirements, you’ve got to calculate the tonnage (chilling capacity) required to deliver the lowest required water temperature to your “process heat load.” That’s the sum of heat that must be removed from 1) the molded or extruded plastic, and 2) heat sources in the process equipment, based on the ...

Get Details
Chiller Sizing Guidelines Made Easy Conair

Chiller Sizing Guidelines Made Easy Conair

Mar 25, 2019 To size a chiller to meet your requirements, you’ve got to calculate the tonnage (chilling capacity) required to deliver the lowest required water temperature to your “process …

Get Details
How to Size a Chiller BV Thermal Systems

How to Size a Chiller BV Thermal Systems

May 30, 2017 General sizing formula: Calculate Temperature Differential (ΔTF) ΔTF = Incoming Water Temperature (F) – Required Chill Water Temperature. Calculate BTU/hr. BTU/hr. = Gallons per hr x 8.33 x ΔTF. Calculate tons of cooling capacity Tons = BTU/hr. 12,000. Oversize the chiller by 20% Ideal Size in Tons = Tons x 1.2.

Get Details
Sizing Chillers Sizing Heat Exchangers How ... - Industrial Chillers

Sizing Chillers Sizing Heat Exchangers How ... - Industrial Chillers

Method A. Watts = [ (DT) F x K] / S. Where. DT= the F difference between incoming and outgoing tap water temperature of your instrument. Measure carefully using the same thermometer for both locations. K = Specific heat multiplied by the density of the fluid being circulated. Use 2,326 for water when calculating load in F.

Get Details
How to sizing chiller for industrial process cooling

How to sizing chiller for industrial process cooling

The final consideration to be aware of in sizing chiller – air-cooled is to recognize that if you have an operation that generates quite a bit of dust, it will be necessary to clean the condenser of …

Get Details
Chillers SMC Corporation of America

Chillers SMC Corporation of America

The Rack Mount Chillers are a temperature control device mountable in a 19-inch rack. Rack mounting recovers desktop or floor space, permitting stacking of related devices and mobility, depending on the rack style. Recirculating fluid removes heat from the process source. The heat is then removed from the fluid by an air or water-cooled ...

Get Details
Expansion Tank Chilled Water Design Guide

Expansion Tank Chilled Water Design Guide

The three main expansion tank sizing equations are (1) open tank, (2) closed tank with no bladder and (3) closed tank with bladder. 3.1 OPEN TANK ... chilled water must achieve before the expansion tank accepts volume. For example, the closed tank has a pressure of 14.7 psia. As the chilled water pressure increases above 14.7 psia, the

Get Details
How to sizing chiller for industrial process cooling

How to sizing chiller for industrial process cooling

Total cooling capacity, Central chillers begin to make sense if the total chilling requirement is 20 tons or more and there are at least three machines that require cooling, all using the same temperature water and in the same production line. Otherwise, a portable chiller will be the correct choice. Initially Cost.

Get Details
Chillers - Trane

Chillers - Trane

Water-Cooled Helical Rotary Chiller. At a glance. Capacity Range: 80 to 450 tons, 60 Hz; 60 to 450 tons, 50 Hz. Refrigerant: R-134a or R-513A. Best Full-load Efficiency: 0.6200 kW/ton (at AHRI conditions) Best Part-load Efficiency: 0.4800 kW/ton. Compressor Type: Helical Rotary. Medium Pressure.

Get Details
How to sizing chiller for industrial process cooling

How to sizing chiller for industrial process cooling

Whether you purchase a portable chiller or a central chiller, you will need to determine if you want one with an air-cooled condenser or a water-cooled condenser. Water-cooled chillers require a secondary cooling source, usually a cooling tower, …

Get Details
News Related
X

CONTACT US

If you are interested in our products, please contact us, your satisfaction is our eternal pursuit!